This past winter I inspected a three-unit brick building in the Fern Rock section of North Philadelphia, in the 19141 ZIP that runs along Logan. The report describes a lower-level unit, a first-floor unit, and a second-floor unit, and rates the overall building condition Good.

But in a multi-unit building, much of what matters is in the garage, the utility room, the panel, and the spaces between the units. Here is what this inspection found, and why the systems that keep three units safe and separate deserve a closer look than a generic checklist gives them.

1. A Missing Electric Meter and Tangled, Unsafe Wiring

The first thing that stood out was that the first-floor unit had no electric meter installed. On a building with separate units, each one is normally metered on its own, so a missing meter is a finding worth following up.

A corroded junction box with loose wires on a stained wall, from a home inspection report on a Fern Rock Philadelphia multi-unit rowhome
A corroded junction box with loose wires, from Bob's report. The report lists open junction boxes and unsecured wiring among the electrical findings.

The wiring around it was worse than the missing meter. There were open junction boxes in the garage hallway and utility room, unsecured branch wiring running loose in the garage, open splices, an open knockout in the back panel, and an abandoned receptacle with a cracked cover plate on the second floor. A first-floor light switch appeared to be on a loose circuit. Individually any one of these is a repair. The report calls for a qualified contractor to evaluate and repair or replace them.

2. Holes in the Garage Ceiling and an Incomplete Fire Barrier

The ceiling between the garage and the living space above had open holes in it. That ceiling is supposed to act as a fire separation, slowing a fire in the garage from spreading into the occupied part of the house. With holes in it, that barrier was incomplete.

Rusted pipes passing through an opening in a ceiling, from a home inspection report on a Fern Rock Philadelphia multi-unit rowhome
Pipes passing through an opening in a ceiling, from Bob's report. The report lists holes in the garage ceiling as an incomplete fire barrier.

In a building with people living directly above and beside a garage, this is a life-safety finding, not a cosmetic one. It is easy to miss because you have to look up and actually understand what that ceiling is for. The report calls for a qualified contractor to evaluate and repair the holes.

3. A Lower-Level Unit With No Independent Heat, and Missing Detectors

The lower-level unit had no independent heating system of its own. The report calls for a qualified contractor to evaluate and install independent heat for proper temperature control. On top of that, there were no smoke or CO detectors in the basement unit and no CO detectors in the first or second floor units.

Missing detectors and a unit with no independent heat are findings that bear directly on safety. The report recommends independent heat for the lower level and smoke and CO detectors on all levels, and a buyer should know about both before closing.

4. Corroded Water Heaters, an Abandoned Tank, and Unsupported Plumbing

The report lists a corroded hot water heater in the garage and an abandoned hot water heater in the utility room. The plumbing was in rough shape as well: water supply lines in the garage were not properly supported, there was a missing shut-off nozzle on a supply line in the garage hallway, and the garage water heater supports were improper.

A white hot water heater beside a blue boiler in a utility room, from a home inspection report on a Fern Rock Philadelphia multi-unit rowhome
The abandoned hot water heater in the utility room, from Bob's report, which recommends removing it. The report also notes one of the hot water heaters has exceeded its designed life.
Piping on a wall beside a water heater in a utility area, from a home inspection report on a Fern Rock Philadelphia multi-unit rowhome
Piping beside a water heater in the utility area, from Bob's report. Unsupported lines can sag, strain their joints, and eventually leak.

I also recommended a heat source in the garage to reduce the risk of the supply lines freezing and bursting, and removal of the abandoned water heater and an abandoned boiler pipe resting on a makeshift support. Every piece of it was documented so the buyer knew what the mechanical rooms needed.

5. Active Water Infiltration in Two Rooms

There was active water infiltration in two places: the second-floor front bedroom, under the front clay tile roof, and the first-floor front living room. A leak was reported in the second-floor front bedroom, and the front lower-level roof had a worn section. The main flat roof was reported to have been seal coated in 2024, and the report advises asking the seller for all documentation.

Water infiltration staining and cracking on a bedroom ceiling in a Fern Rock Philadelphia rowhome, found during a home inspection
Active water infiltration on the front bedroom ceiling, under the clay tile roof. The report calls for a contractor to seal the water source.

Active water coming through the ceiling in two separate rooms is not something to defer. It rots framing and feeds mold if it is left alone. The report calls for a qualified contractor to seal the water source and repair any damage. On a rowhome with a clay tile front roof and a flat back roof, those are two different roofing systems with two different failure points, and both were showing.

6. A Chimney With No Visible Flue Liner and Open Brick Joints

The chimney had no visible metal liner and open brick joints on sections of it. A flue that vents combustion appliances needs an intact liner to safely carry exhaust up and out, and a missing liner is a safety hazard, not a maintenance item.

Brick chimney with open and deteriorated mortar joints above a clay tile roof on a Fern Rock Philadelphia rowhome, documented during a home inspection
The brick chimney with open, deteriorated mortar joints. Open joints let water into the masonry, and with no visible flue liner this chimney was flagged for evaluation by a qualified contractor.

Open brick joints let water into the masonry, where it freezes, expands, and pulls the chimney apart over the winters. Combined with the missing liner, the chimney needed a qualified contractor to evaluate and repair it. This is a common finding on older Philadelphia masonry, and it is one worth catching before the next freeze cycle makes it worse.

7. Deteriorated Masonry, Gutters, and Exterior Safety Hazards

The masonry needed attention in several places. There were cracks and spalling on sections of the front foundation wall, and cracks and open brick joints on sections of the back walls. The gutters and downspouts were failing too: the front downspout was leaking, the back downspout was damaged, and the front gutter was damaged.

Open and deteriorated brick mortar joints on the rear masonry wall of a Fern Rock Philadelphia rowhome, with loose wiring, documented during a home inspection
Open brick joints and deterioration on the back wall, above an older stone foundation, with loose wiring strung across it. Open joints and failing gutters work together to drive water into the masonry.

On the exterior there were also real trip and fall hazards to flag: cracks in the front sidewalk and front walk, cracks in the front steps, and missing handrails on the front steps. Failing gutters and open masonry joints feed each other, because water that is not carried away runs down the wall and into the joints. Repointing the masonry, fixing the drainage, and addressing the step and walkway hazards were all documented so the buyer could plan the work rather than trip over it.

What Buyers Should Expect From Home Inspections in Fern Rock

This inspection found a missing meter, unsafe wiring, an incomplete fire barrier, a unit with no independent heat, missing detectors, corroded mechanicals, active water infiltration, and deteriorated masonry, in a building the report rates Good overall. That gap between the overall rating and what the individual systems show is why a multi-unit building deserves a close look.

What makes an inspection in Fern Rock different is knowing to look at the building as three units, not one. Buyers looking at multi-unit rowhomes here, and in the rest of the city, are often focused on the kitchen and the finishes, and those are exactly the parts a generic checklist confirms while it rushes past the missing meter and the holes in the garage ceiling. Catching those comes from having inspected a lot of these conversions in this specific housing stock.

If you are buying a rowhome or a multi-unit property in Fern Rock or the surrounding North Philadelphia neighborhoods, schedule an inspection with All Seasons. I personally perform every inspection, and I know how these buildings are put together.